ANSI C136.41 dimmable dimmpin receptacle socket photocontroling 7

ANSI C136.41 dimmable dimmpin receptacle socket photocontroling 7

Model No.︰240

Brand Name︰JL

Country of Origin︰China

Unit Price︰US $ 1 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

roduct Summary 
The entire JL-240 series twist-lock receptacles were designed for the lanterns those intended to have an 
ANSI C136.10-2006 receptacle to fit a twist-lock photocontrol. This series conform newly published ANSI 
C136.41-2013 to allow a LED lamp multi-controlled through the receptacle, and obtained cRUus 
certificates under UL file E188110. 
This item JL-240TL-XA1412R7P offers 4 gold-plated low voltage pads on the top surface to fit 
photocontrol has ANSI C136.41 conforming spring contacts, and offers 4 corresponding wires at rear back 
for signal connection. 
This item offers 360 degree rotation limiting feature to conform ANSI C136.10-2010 requirements. After 
simply fit its Rear Seat onto a lamp housing with 2 screws, the assembled receptacle body can be handy 
snapped on the Seat for mechanical installation completed. Rotation will be held during photocontrol 
installation or removal by pressure applied vertically. 
This item has multiple gaskets built-in already for IP65 protection. 


Technical Data 
Model No. JL-240TL-XA1412R7P 
Power Volt Range 0~480VAC 
Rated Frequency 50/60Hz 
Power Loading 15A max. / AWG#16: 10A max. 
Signal Loading 30VDC, 0.25A max. 
Ambient Temperature External* -40ºC ~ +70ºC 
Receptacle UV stabilized Polycarbonate (UL94 5VA) 
Power Contact Solid Brass 
Signal Contact Nickel plated Phosphor Bronze, Gold plated 
Gasket Thermal Elastromer (UL94 V-0) 
Power Lead 14AWG, AWM1015 
Material 
Signal Lead 18AWG, AWM1015 
Leads 12" 
Overall Dimensions (mm) 69Dia.x 38 
* Ambient Temperature rating is for the receptacle body outside luminaire. 
Installation 
Disconnect power; wire the receptacle according to the diagram below. An arrow indicating 
NORTH on the top of the receptacle is used to assist correct direction. Push the photocontrol on 
and turn it clockwise to lock into the receptacle

Payment Terms︰ TT